• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
BACKUP ALARM REPLACEMENT
BATTERIES REPLACEMENT

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  253    254    255    256    257  258  259    260    261    262    263  
img
TM 5-3805-290-23-2
BACKUP ALARM REPLACEMENT - CONTINUED
0076 00
REMOVAL
1.
Cut and discard tiedown strap (1) from wiring harness
(2).
2.
Disconnect wiring harness (2) from backup alarm (3).
3.
Remove two bolts (4), washers (5), and backup alarm
(3) from machine.
427-B0244
INSTALLATION
1.
Install backup alarm (3), two washers (5), and bolts (4) on machine.
2.
Connect wiring harness (2) to backup alarm (3).
3.
Install new tiedown strap (1) on wiring harness (2).
4.
Close fan housing access door (TM 5-3805-290-10).
5.
Verify correct operation of backup alarm (TM 5-3805-290-10).
END OF WORK PACKAGE
0076 00-2