TM 5-3805-290-23-2
BATTERIES REPLACEMENT - CONTINUED
0077 00
REMOVAL
1.
Pull back two protective covers (1) from battery terminals (2).
WARN I N G
Be careful not to touch tool used to disconnect cable clamp to any part of machine. Sparks may occur
resulting in injury to personnel or damage to equipment.
N OT E
Disconnect negative (black) cable
first.
Arctic configuration is shown.
2.
Loosen two nuts (3) and disconnect cable clamps (4
and 5) from battery terminals (2).
3.
Repeat steps 1 and 2 for other battery.
427-B0832