2
TM 5-3805-290-23-2
BACKUP ALARM REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Equipment Conditions - Continued
Maintenance Level
Unit
Work tool lowered to ground (TM 5-3805-290-10)
Parking brake engaged (TM 5-3805-290-10)
Tools and Special Tools
Wheels chocked
Battery disconnect switch in OFF position (TM 5-
Materials/Parts
3805-290-10)
Fan housing access door opened (TM 5-3805-290-
10)
Personnel Required
Drawings Required
MOS 62B, Construction Equipment Repairer
TM 5-3805-290-23P, Figure 54
Equipment Conditions
Estimated Time to Complete Task
Machine parked on level ground (TM 5-3805-290-
10)
0.3 hr
WARN I N G
Ensure battery disconnect switch is in OFF position before performing this task. Failure to follow this
warning may result in injury to personnel or damage to equipment.