ENGINE - CONTINUED
ENGINE - CONTINUED

Operators Manual For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  146    147    148    149    150  151  152    153    154    155    156  
img
. . . . . . . . .
TM 5-3805-291-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
3.
Engine Does Not Develop Full Power.
WARN I N G
If NBC exposure is suspected, personnel wearing protective
equipment must handle all air cleaner media. Consult your
NBC Officer or NBC NCO for appropriate handling or dis-
posal procedures.
Refer to FM 3-11.3, Multiservice Tactics, Techniques,
and Procedures for Chemical, Biological, Radiological,
and Nuclear Contamination Avoidance, and FM 3-11.5,
Multiservice Tactics, Techniques, and Procedures for
Chemical,  Biological,  Radiological,  and  Nuclear
Decontamination.
NBC contaminated filters must be handled using adequate
precautions and must be disposed of by trained personnel.
Failure to follow these warnings may cause injury or death.
Check front dash indicator (WP 0004 If indicator is on, service engine air
cleaner (WP 0014 00) and retest
00).
step. If problem still exists, notify
Unit Maintenance.
Check front dash indicator (WP 0004 If indicator is on, service engine air
4.
Engine Does Not Idle Properly.
cleaner (WP 0014 00) and retest
00).
step. If problem still exists, notify
Unit Maintenance.
1.
Check position of transmission
Place transmission control lever
5.
Engine Fails to Crank When Engine
control lever and remote F/N/R
and remote F/N/R switch in N
Start Switch is Turned to START.
switch.
(NEUTRAL). If problem still
exists, go to test step 2.
2.
Check position of battery
Place battery disconnect switch to
disconnect switch (WP 0004 00).
ON. If problem still exists, go to
test step 3.
3.
Check for blown engine start
If  fuse  is  blown,  request
switch fuse (WP 0016 00).
replacement  fuse  from  Unit
Maintenance. If fuse is good, go to
test step 4.
N OTE
A 30-minute cool down time may be required before circuit breaker
automatically resets.
4.
Auxiliary circuit breaker may have Allow circuit breaker to reset. If
tripped (WP 0016 00).
problem still exists, go to test step
5.
0010 00-9