TM 5-3805-291-23-1
TROUBLESHOOTING SYMPTOM INDEX - CONTINUED
0007 00
Table 1. MID 036 Engine Control - Continued.
TROUBLE-
CID
SHOOTING
FMI
FAULT
PROCEDURE
CODE
DESCRIPTION
FAULT CONDITIONS/EFFECTS
PAGE
Wrong Response from
This code is generated when the engine ECM for the engine is not
0596 12
Implement ECM
receiving complete information from the implement ECM. When this
code is generated, the code is logged and all features that depend on
input from the implement ECM will be disabled. This code has no effect
on engine performance.
Intake Manifold Pressure This code is generated when the engine ECM detects a signal voltage
1785 03
Sensor Voltage High
above normal. When this code is generated, the code is logged, the
engine ECM flags intake manifold pressure as invalid data and a default
value is used, and the engine power will be derated.
Intake Manifold Pressure This code is generated when the engine ECM detects a signal voltage
1785 04
Sensor Voltage Low
below normal. When this code is generated, the code is logged, the
engine ECM flags intake manifold pressure as invalid data and a default
value is used, and the engine power will be derated.
Intake Manifold Pressure This code is generated when the engine ECM no change in the signal
1785 10
Signal Abnormal Rate of from the sensor. When this code is generated, the code is logged, the
Change
engine ECM flags intake manifold pressure as invalid data and a default
value is used, and the engine power will be derated.
Ether Injection Control
This code is generated when the engine ECM detects low current in the
2417 05
circuit. When this code is generated, the code is logged and the engine
may be difficult to start.
Ether Injection Control
This code is generated when the engine ECM detects excessive current
flow in the circuit. When this code is generated, the code is logged and
2417 06
the engine may be difficult to start.
0007 00-12