1. Check engine oil level (TM 5-3805-291-10). If engine oil level is low, add engine oil to
E360
obtain correct engine oil level. If problem
still exists, go to Test 2.
If damaged, replace engine oil pump and/
2. Air leakage or restriction in oil pump or
suction tube will cause cavitation and loss of or suction tube (WP 0182 00). If problem
still exists, go to Test 3.
oil pressure. Check oil pump and suction
tube (WP 0182 00).
3. Check for engine oil bypass valves stuck in
If engine oil bypass valves are stuck in
open position.
open position, replace engine oil filter base
Test 4.
If engine oil is contaminated, change
4. Check for engine oil that is contaminated
with fuel or coolant. High engine oil level in
problem still exists, go to Test 5.
5. Check for an oil line that is open, broken, or
Repair or replace lines as necessary (WP
disconnected.
1. Verify cooling system is filled to proper
If coolant level is too low, add coolant (WP
E361
level.
0041 00). If problem still exists, go to Test
2.
2. Check radiator between fins and inside
1. Remove all restrictions.
radiator core for damage, debris, dirt, and
2. If problem still exists, go to Test 3
deposits.
3. Check mixture of anitfreeze and water (TB
Add water or coolant as necessary (WP
750-651).
0041 00). If problem still exists, go to Test
4.
4. Check water temperature regulator by
If problem still exists, reinstall old
replacing it with a known good one.
regulator, go to Test 5.
5. Remove water pump and check for damage
If damaged, replace water pump. If
problem still exists, go to Test 6.
1. If fan is inoperative, troubleshoot fan.
2. If problem still exists, go to Test 7.
7. Check for combustion gas in cooling system. If combustion gas is found, replace
cylinder head and /or cylinder head gasket
(WP 0172 00).
8. Check cooling system hoses and clamps for
If damaged, replace hose or clamps. If
damage, restriction, or softness (WP 0043
problem still exists, go to Test 9.
00).
9. Check for restriction in air inlet system (WP
1. Remove any restrictions.
2. If problem still exists, go to Test 10.
10.Check for restriction in exhaust system (WP Remove any restrictions.