TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 3. Powertrain Control - Continued.
(MID 081)
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Disconnect wiring harness
0444 06 - Continued.
connector(s) from powertrain ECM
(WP 0063 00).
(d) At wiring harness connector, measure
greater than 5,000 Ohms, go to Test 3.
(wire 306-GN) to all contacts used in
wiring harness connectors for ECM.
greater than 5,000 Ohms, short is
between J2-7 (wire 306-GN) and circuit
with low resistance measurement.
Replace wiring harness in question (WP
0195 00 thru WP 0201 00).
3. Check if diagnostic code remains active.
(a) Inspect and clean harness connector
contacts.
(b) Reconnect all wiring harness
connectors.
(c) Operate machine (TM 5-3805-291-
10).
(d) Use messenger to check status of CID
1. If CID 0444 FMI 06 is active, exit this
0444 FMI 06 (TM 5-3805-291-10).
procedure and repeat procedure. If
cause of diagnostic code is not found,
replace powertrain ECM (WP 0063 00).
2. If CID 0444 FMI 06 is not active,
diagnostic code does not exist at this
time.