TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 3. Powertrain Control - Continued.
(MID 081)
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
(d) At wiring harness connector, measure 1. If each resistance measurement is
1402 06 - Continued.
resistance from signal contact J1-62
greater than 5,000 Ohms, go to Test 3.
(wire 752-YL) to all sources of ground. 2. If each resistance measurement is not
greater than 5,000 Ohms, short is
between J1-11 (wire 752-YL) and the
ground circuit. Replace wiring harness
in question (WP 0195 00 thru WP 0201
00).
3. Check if diagnostic code remains active.
(a) Inspect and clean wiring harness
connector contacts.
(b) Reconnect all wiring harness
connectors.
(c) Operate machine (TM 5-3805-291-
10).
(d) Use messenger to check status of CID
1. If CID 1402 FMI 06 is active, exit this
1402 FMI 06 (TM 5-3805-291-10).
procedure and repeat this procedure. If
cause of the diagnostic code is not
found, replace powertrain ECM (WP
0063 00).
2. If CID 1402 FMI 06 is not active,
diagnostic code does not exist at this
time. Resume normal machine
operation.
0009 00-119