TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(d) Reconnect all connectors
0296 09 - Continued.
(e) Ensure CID 0296 FMI 09 is active. 1. If diagnostic code indicator is active and
diagnostic code is active, go to Test 2.
2. If diagnostic code indicator is inactive,
wiring harness connection has failed.
Diagnostic code is inactive. An
intermittent connection may exist in
CAT Data Link circuits of wiring
harness. Watch for a recurrence of this
diagnostic code.
2. Check for short in wiring harness.
(a) Battery disconnect switch remains
in OFF position (TM 5-3805-291-
10).
(b) Disconnect wiring harness from
implement ECM (WP 0060 00) and
powertrain ECM (WP 0063 00).
(c) At wiring harness connector for
implement ECM, measure
wiring harness circuit resistance is
resistance between contacts J1-20
correct. Go to Test 3.
(wire 945-BR) and J1-10 (wire
944-OR).
replace wiring harness in question (WP
0195 00 thru WP 0201 00).
3. Check for open circuit in wiring harness.
(a) Battery disconnect switch remains
in OFF position (TM 5-3805-291-
10).
(b) Implement ECM and powertrain
ECM remain disconnected from
wiring harness.
(c) At wiring harness connector for
powertrain ECM, place a jumper
between contacts J1-20 (wire 945-
BR) and J1-10 (wire 944-OR).
(d) At wiring harness connector for
Test 4.
implement ECM, check resistance
between contacts J1-20 (wire 945-
BR) and J1-10 (wire 944-OR).
replace wiring harness in question (WP
0195 00 thru WP 0201 00).
powertrain ECM.
0009 00-170