• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SECONDARY STEERING PUMP AND ELECTRIC MOTOR MAINTENANCE - CONTINUED
STEERING HOSES, LINES, AND FITTINGS REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  335    336    337    338    339  340  341    342    343    344    345  
img
. . . . . . . . . . . . . . . .
10
TM 5-3805-291-23-2
STEERING HOSES, LINES, AND FITTINGS REPLACEMENT
0124 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Personnel Required
Maintenance Level
MOS 62B, Construction Equipment Repairer
Unit
References
Tools and Special Tools
TM 5-3805-291-10
Tool kit, general mechanic's, automotive (Item 90,
WP 0232 00)
WP 0125 00
WP 0127 00
Materials/Parts
WP 0128 00
Cap set, protective (Item 6, WP 0233 00)
WP 0159 00
Oil, lubricating, OE/HDO-5/40 (Item 27, WP 0233
00)
Equipment Conditions
Oil, lubricating, OE/HDO-15/40 (Item 28, WP
Hydraulic tank drained (WP 0148 00)
0233 00)
Cab removed (WP 0132 00)
Oil, lubricating, OEA-30, Arctic (Item 29, WP
Drawings Required
0233 00)
TM 5-3805-291-23P, Figures 110 and 111
Rag, wiping (Item 35, WP 0233 00)
Tag, marker (Item 43, WP 0233 00)
Estimated Time to Complete Task
O-ring (24)
4.0 hr
WARN I N G
DO NOT disconnect or remove any hydraulic system line or fitting unless engine is shut down and
hydraulic system pressure has been relieved. Tighten all connections before applying pressure. Escap-
ing hydraulic fluid under pressure can penetrate the skin, causing injury to personnel.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulic lines. Failure to follow this warning may result in injury to personnel.
Hydraulic oil used in the performance of maintenance can be very slippery. Immediately wipe up any
spills. Failure to follow this warning may result in injury to personnel.
C AU T I O N
Wipe area clean around all connections to be opened during removal. Cap lines and hoses and plug
openings after removing lines. Contamination of system could result in premature failure.
0124 00-1