ENGINE CONTINUED
ENGINE CONTINUED

Operators Manual For M400T And M400W
Page Navigation
  124    125    126    127    128  129  130    131    132    133    134  
img
. . . .
TM 5-3805-292-10
0018
0.
ENGINE CONTINUED
MALFUNCTION
Engine does not run smoothly at low idle.
WARNING
If NBC exposure is suspected, personnel wearing protective equipment should handle all
air cleaner media. Consult your NBC Officer or NBC NCO for appropriate handling or
disposal procedures.
Refer to FM 3-11.3, Multiservice Tactics, Techniques, and Procedures for Chemical,
Biological, Radiological, and Nuclear Contamination Avoidance, and FM 3-11.5
Multiservice Tactics, Techniques, and Procedures for Chemical, Biological, Radiological,
and Nuclear Decontamination.
NBC contaminated filters must be handled using adequate precautions and must be
disposed of by trained personnel.
Failure to follow these warnings may result in injury or death to personnel.
CORRECTIVE ACTION
Step 1.
Check air filter element (WP 0021).
a.
Clean or replace primary air filter (WP 0021).
b.
If secondary air filter element is clogged, notify Field Maintenance.
c.
If problem still exists, proceed to step 3.
Step 2.
Drain water from fuel/water separator (WP 0020).
If no water present and problem still exists, notify Field Maintenance.
MALFUNCTION
Engine will not crank.
CORRECTIVE ACTION
Step 1.
Ensure auxiliary hydraulic control pedal is in neutral position.
a.
Place auxiliary hydraulic control pedal in neutral position.
b.
If problem still exists, proceed to step 2.
Step 2.
Check both batteries for dirty, loose, or damaged battery cables (WP 0020).
If batteries or cables are dirty, loose, or damaged, notify Field Maintenance.