Table 2. Preventive Maintenance Checks and Services (PMCS) for the Work Tool Attachments - Continued.
Figure 1. Air Cleaner Housing Cover.

Operators Manual For M400T And M400W
Page Navigation
  202    203    204    205    206  207  208    209    210    211    212  
img
. . . . . .
6
TM 5-3805-292-10
0021
OPERATOR MAINTENANCE
-
ENGINE AIR CLEANER SERVICE
00
21
SERVICE
INITIAL SETUP
Equipment Conditions - Continued
Materials/Parts
0
0
Rag, Wiping (WP 0033, Item 12)
Engine off (WP 0005)
0
0
Parking brake engaged (WP 0005)
0
Equipment Conditions
0
Estimated Time To Complete
Machine parked on level ground (WP 0005)
0
0
Loader arms lowered to ground (WP 0005)
0.5 Hrs
0
0
0
WARNING
If NBC exposure is suspected, personnel wearing protective equipment must handle all air
cleaner media. Contaminated filters must be handled using adequate precautions and
must be disposed of by trained personnel. Consult your NBC Officer or NBC NCO for
appropriate handling or disposal procedures. Failure to follow this warning may cause
injury or death to personnel.
NOTE
Air cleaner primary element may be cleaned several times, as long as it is not damaged.
However, it should be replaced at least once each year.
Do not clean air cleaner secondary element. If air cleaner secondary element appears
clogged or damaged, notify Field Maintenance. It should be replaced by Field
Maintenance only.
0021-1