Figure 2. Horn.
Figure 1. HVAC Temperature Control Switch.

Field Maintenance Manual For M400T And M400W
Page Navigation
  1027    1028    1029    1030    1031  1032  1033    1034    1035    1036    1037  
img
. . . . . .
4
TM 5-3805-292-23
0153
FIELD MAINTENANCE
-
HVAC TEMPERATURE CONTROL SWITCH REPLACEMENT
01
53
REMOVAL, INSTALLATION
INITIAL SETUP
Tools and Special Tools
References
0
0
Tool Kit, General Mechanic's (WP 0178, Item
TM 5-3805-292-10
0
33)
TM 5-3805-292-23P, Figure 71
0
0
SATS (WP 0178, Item 30)
0
Equipment Conditions
0
Materials/Parts
Battery power disconnected (WP 0142)
0
0
Rag, Wiping (WP 0179, Item 19)
Post LH console removed (WP 0094)
0
0
Estimated Time to Complete
0
0.9 Hr
0
0153-1