TM 5-3805-292-23
0079
INSTALLATION CONTINUED
11. Remove caps and plugs from lines and ports.
12. Lubricate two new O-rings (Figure 9, Items 10 and 13) with clean hydraulic fluid and install on lines (Figure 9,
Items 5 and 14).
N OT E
Install lines and fittings as noted on removal.
13. Install four fittings (Figure 9, Items 1, 2, 3, and 4) and connect four powertrain lines (Figure 9, Items 5, 11, 12,
and 14), to machine.
14. Install two tubes (Figure 9, Item 9), clamps (Figure 9, Item 8), bolts (Figure 9, Item 15), spacer (Figure 9, Item
7), and two nuts (Figure 9, Item 6) on lines.
Figure 9. Powertrain Lines and Fittings.