Figure 1. Auxiliary Hydraulic Cable.
BOOM OVERRIDE VALVE REPLACEMENT

Field Maintenance Manual For M400T And M400W
Page Navigation
  560    561    562    563    564  565  566    567    568    569    570  
img
. .
TM 5-3805-292-23
0080
CLEANING AND INSPECTION CONTINUED
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
2. Dry parts with compressed air.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00080
N OT E
Route cable as noted during removal.
It may be necessary to loosen nut(s) in order to align pin and clevis.
1. Install plate (Figure 1, Item 7) on machine.
2. Position clevis pin (Figure 1, Item 4), install new cotter pin (Figure 1, Item 5), and rotate bracket (Figure 1,
Item 3).
3. Position auxiliary hydraulic cable (Figure 1, Item 1) and install two bolts (Figure 1, Item 6).
4. Tighten jam nut (Figure 1, Item 2).
END OF TASK
FOLLOW-ON TASKS
00080
1. Install auxiliary hydraulic pedal (WP 0085).
2. Install cab cover plate (WP 0095).
3. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE
0080-3/(4 blank)