TM 5-3805-292-23
0080
REMOVAL
00080
N OT E
Note routing of cable before removal to aid in installation.
Gain access through removed cover plate.
Remove and discard tiedown straps as necessary.
1. Loosen jam nut (Figure 1, Item 2).
2. Rotate bracket (Figure 1, Item 3) and remove cotter pin (Figure 1, Item 5) and clevis pin (Figure 1, Item 4) from
machine. Discard cotter pin.
3. Remove two bolts (Figure 1, Item 6) and auxiliary hydraulic cable (Figure 1, Item 1) from machine.
4. Remove plate (Figure 1, Item 7) from machine.
Figure 1. Auxiliary Hydraulic Cable.
0080
END OF TASK
CLEANING AND INSPECTION
00080
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.