BOOM OVERRIDE VALVE REPLACEMENT - Continued
Figure 1. Clamps.

Field Maintenance Manual For M400T And M400W
Page Navigation
  565    566    567    568    569  570  571    572    573    574    575  
img
. . . . . . . . . . .
6
TM 5-3805-292-23
0082
FIELD MAINTENANCE
-
HYDRAULIC HOSES, LINES AND FITTINGS REPLACEMENT
0082
REMOVAL, CLEANING AND INSPECTION, INSTALLATION
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's (WP 0178, Item
TM 5-3805-292-10
0
33)
TM 5-3805-292-23P, Figure 56
0
0
SATS (WP 0178, Item 30)
0
Equipment Conditions
0
Materials/Parts
Hydraulic pressure relieved (WP 0172)
0
0
Cap Set, Protective (WP 0179, Item 2)
Hydraulic reservoir drained (WP 0009)
0
0
Cleaning Compound, Solvent, Type III (WP
Seat removed (WP 0126)
0
0179, Item 3)
0
Estimated Time to Complete
Oil, Lubricating, OE/HDO-10 (WP 0179, Item
0
Hydraulic hoses: 0.5 Hr ea.
16)
0
0
Tag, Marker (WP 0179, Item 30)
Hydraulic lines: 0.5 Hr ea.
0
0
Lockwasher
Fittings: 0.5 Hr ea.
0
0
Locknut
0
WARN I N G
When servicing this machne, performing maintenance, or disposing of hazardous
i
materials, consult your unit/local hazardous waste disposal center or safety office for local
regulatory guidance. If further information is needed, please contact The Army
Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system lines or fitting unless engine is shut
down and hydraulic system pressure has been relieved. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin.
At operating temperature, hydraulic oil is hot.Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
If loader arm must be raised to gain access to hydraulic hoses, lines, or fittings, support
strut must be installed.
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic hose and line ends along with component connections during removal to
protect against contamination. Failure to follow this caution may result in damage to
equipment.
0082-1


Privacy Statement