TM 5-3805-292-23
0091
CLEANING AND INSPECTION CONTINUED
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00091
N OT E
Position condenser so discharge fitting faces front of machine.
1. Position condenser (Figure 1, Item 7) on machine and install four washers, (Figure 1, Item 4), spacers (Figure
1, Item 3), washers (Figure 1, Item 2), and mounting capscrews (Figure 1, Item 1).
2. Lubricate two new O-rings (Figure 1, Item 5) with refrigerant oil and install O-rings in hoses (Figure 1, Item 6).
3. Connect two hoses (Figure 1, Item 6) to condenser (Figure 1, Item 7).
END OF TASK
FOLLOW-ON TASKS
00091
1. Evacuate and recharge A/C system with refrigerant (WP 0093).
2. Close upper rear access door (TM 5-3805-292-10).
3. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE