Figure 1. A/C Receiver/Dryer.
A/C SYSTEM MAINTENANCE

Field Maintenance Manual For M400T And M400W
Page Navigation
  636    637    638    639    640  641  642    643    644    645    646  
img
.
TM 5-3805-292-23
0092
INSTALLATION
00092
1. Position A/C receiver/dryer (Figure 1, Item 5) in clamp (Figure 1, Item 4).
2. Install two bolts and nuts (Figure 1, Item 1) on clamp (Figure 1, Item 4).
3. Lubricate two new O-rings (Figure 1, Item 3) with refrigerant oil and install in hoses (Figure 1, Item 2).
4. Connect two hoses (Figure 1, Item 2) to A/C receiver/dryer (Figure 1, Item 5).
END OF TASK
FOLLOW-ON TASKS
00092
1. Evacuate and recharge A/C system with refrigerant (WP 0093).
2. Install floor plate (TM 5-3805-292-10).
3. Install access cover (TM 5-3805-292-10).
4. Verify correct operation of machine (TM 5-3805-292-10).
END OF TASK
END OF WORK PACKAGE