A/C CONDENSER REPLACEMENT
A/C CONDENSER REPLACEMENT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  632    633    634    635    636  637  638    639    640    641    642  
img
.
TM 5-3805-292-23
0091
REMOVAL
00091
1. Disconnect two A/C hoses (Figure 1, Item 6) from condenser (Figure 1, Item 7). Remove and discard two
O-rings (Figure 1, Item 5).
2. Remove four mounting capscrews (Figure 1, Item 1), washers (Figure 1, Item 2), spacers (Figure 1, Item 3),
and washers (Figure 1, Item 4) from condenser (Figure 1, Item 7).
3. Remove condenser (Figure 1, Item 7) from machine.
Figure 1. A/C Condenser.
0091
END OF TASK
CLEANING AND INSPECTION
00091
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.