• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Battery Compartment.
BATTERIES REPLACEMENT - Continued

Field Maintenance Manual For M400T And M400W
Page Navigation
  939    940    941    942    943  944  945    946    947    948    949  
img
. .
TM 5-3805-292-23
0141
CLEANING AND INSPECTION
000141
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0172).
END OF TASK
INSTALLATION
000141
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Failure to follow this warning may result in injury to
personnel.
N OT E
Each battery weighs 60 lb (27.2 kg).
1. Install two batteries (Figure 2, Item 9) in battery compartment.
2. Install rod (Figure 2, Item 2) in battery compartment.
3. Install hold-down (Figure 2, Item 5), washer (Figure 2, Item 4), and nut (Figure 2, Item 3) on rod (Figure 2, Item
2).
N OT E
Connect negative (black) cable last.
4. Connect six battery cables (Figure 2, Item 6) to batteries (Figure 2, Item 9).
5. Install four nuts (Figure 2, Item 7) and covers (Figure 2, Item 1) on batteries (Figure 2, Item 9).
6. Install fuse (Figure 2, Item 8).
Figure 2. Battery Compartment.
0141
END OF TASK
0141-3