TM 5-3805-298-23-1
0108
Table 1. 882 Implement Lockout Solenoid Diagnostic Codes - Continued.
0108
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
4. Remove transmission ECM cover
882-3 Implement Lockout
(WP 0266).
Normal - Continued
5. Disconnect connector C-C13
Transmission ECM J2.
harness (WP 0291).
between connector C-C13
Proceed to Test Step 3.
No Continuity - Replace transmission
and all other C-C13 terminals.
ECM (WP 0266).
Proceed to Test Step 3.
Test Step 3. Verify Malfunction Is
Resolved.
1. Ensure all wiring harness
connectors are connected.
2. Install transmission ECM cover
(WP 0266).
3. Install left lower cab access panels
(WP 0347).
4. Using MSD, check for active
Diagnostic Code 882-3 Implement
Lockout Solenoid Voltage Is Above
Normal Becomes Inactive -
Troubleshooting complete.
Diagnostic Code 882-3 Implement
Lockout Solenoid Voltage Is Above
Normal Remains Active - Repeat
troubleshooting from the beginning.
NOTE
882-5 Implement Lockout
Solenoid Current Below
Always inspect wiring harness connectors that are involved in the circuit.
Normal
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure and
that all connections are in good condition. If a problem with the
connection is found, correct the problem and verify that this malfunction
or diagnostic code is active before performing this procedure.
Perform open or short-circuit test at each wiring harness connection to
identify the correct wiring harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.