Figure 1. Ammeter.
Figure 3. Alternator Terminals.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  316    317    318    319    320  321  322    323    324    325    326  
img
.
TM 5-3805-298-23-2
0165
CHARGING SYSTEM TEST CONTINUED
5. Connect clamp (Figure 2, Item 3) of ammeter (Figure 2, Item 1) around positive alternator cable
(Figure 2, Item 2) with arrow (Figure 2, Item 4) facing direction of current flow (away from alternator).
6. While monitoring ammeter (Figure 2, Item 1), have assistant start engine and then fully depress and hold
throttle pedal (TM 5-3805-298-10).
a. If initial charging current is greater than 70 amps, proceed to step 8.
b. If initial charging current is less than 70 amps, alternator is faulty.
c.
Remove ammeter (Figure 2, Item 1) from machine.
Figure 2. Ammeter Connection.
0165
0165-3