Figure 25. 5,800 psi (40,000 kPa) Gauge Assembly.
Figure 27. Pump Cutoff Pressure Adjustment.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  346    347    348    349    350  351  352    353    354    355    356  
img
.
TM 5-3805-298-23-2
0166
PUMP CUTOFF PRESSURE TEST CONTINUED
13. Pressure reading should be 3,756 51 psi (25,900 350 kPa).
14. Tilt the bucket level to the ground and lower the bucket to the ground (TM 5-3805-298-10).
15. Turn ignition switch and battery disconnect switch to OFF position (TM 5-3805-298-10).
16. Disconnect hose 177-7861 (Figure 25, Item 2) from piston pump pressure connection (Figure 26, Item 2).
17. Install cap (Figure 26, Item 1) on piston pump pressure connection (Figure 26, Item 2).
18. Install right ladder and right lower cab access panels (WP 0347).
Figure 26. Piston Pump Pressure Connection.
0166
END OF TASK