MARGIN PRESSURE TEST CONTINUED
8. Apply sealant on threads of 5,800 psi (40,000 kPa) gauge (Figure 33, Item 1) and a 6V-3966 valved nipple
(Figure 33, Item 3) from pressure gauge kit.
9. Install adapter (Figure 33, Item 2) on 5,800 psi (40,000 kPa) gauge (Figure 33, Item 1).
10. Install 6V-3966 valved nipple (Figure 33, Item 3) on adapter (Figure 33, Item 2).
11. Connect hose 177-7861 (Figure 33, Item 4), from pressure gauge kit, to 6V-3966 valved nipple
(Figure 33, Item 3).
Figure 33. 5,800 psi (40,000 kPa) Gauge Assembly.