TM 5-3805-298-23-2
0166
MARGIN PRESSURE TEST CONTINUED
1. Apply sealant on threads of 5,800 psi (40,000 kPa) gauge (Figure 31, Item 1) and a 6V-3966 valved nipple
(Figure 31, Item 3) from pressure gauge kit.
2. Install adapter (Figure 31, Item 2) on 5,800 psi (40,000 kPa) gauge (Figure 31, Item 1).
3. Install 6V-3966 valved nipple (Figure 31, Item 3) on adapter (Figure 31, Item 2).
4. Connect hose 177-7861 (Figure 31, Item 4), from pressure gauge kit, to 6V-3966 valved nipple
(Figure 31, Item 3).
Figure 31. 5,800 psi (40,000 kPa) Gauge Assembly.
0166