• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MARGIN PRESSURE TEST
Figure 32. Signal Pressure Connector.

Field Maintenance Manual For 924H Wheel Loader -2 Page Navigation
  352    353    354    355    356  357  358    359    360    361    362  
img
.
TM 5-3805-298-23-2
0166
MARGIN PRESSURE TEST CONTINUED
1. Apply sealant on threads of 5,800 psi (40,000 kPa) gauge (Figure 31, Item 1) and a 6V-3966 valved nipple
(Figure 31, Item 3) from pressure gauge kit.
2. Install adapter (Figure 31, Item 2) on 5,800 psi (40,000 kPa) gauge (Figure 31, Item 1).
3. Install 6V-3966 valved nipple (Figure 31, Item 3) on adapter (Figure 31, Item 2).
4. Connect hose 177-7861 (Figure 31, Item 4), from pressure gauge kit, to 6V-3966 valved nipple
(Figure 31, Item 3).
Figure 31. 5,800 psi (40,000 kPa) Gauge Assembly.
0166
0166-35


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.