TM 5-2420-231-23-2
0108
DISASSEMBLY CONTINUED
Figure 2. Flywheel Housing Plugs.
0108
END OF TASK
CLEANING AND INSPECTION
0108
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0369).
END OF TASK
ASSEMBLY
0108
1. Install two plugs (Figure 2, Item 2) and new O-rings (Figure 2, Item 3) on flywheel housing (Figure 2, Item 1).
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
2. Apply sealant to pipe plug (Figure 2, Item 4).
3. Install pipe plug (Figure 2, Item 4) in flywheel housing (Figure 2, Item 1).
4. Install plastic threaded plug (Figure 2, Item 5) in flywheel housing (Figure 2, Item 1).
5. Apply sealant to flywheel housing (Figure 2, Item 1) sealing surface.
END OF TASK