8
TM 5-2420-231-23-2
FIELD MAINTENANCE
-
EQUALIZER CABLES REPLACEMENT
0196
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
References
Tools and Special Tools
Tool Kit, General Mechanic's
WP 0369
0
0
(WP 0376, Item 117)
WP 0370
0
WP 0374 (Group Number 0319 and 0821)
Materials/Parts
0
Rag, Wiping (WP 0375, Item 25)
Equipment Conditions
0
Tag, Marker (WP 0375, Item 33)
0
0
Tiedown Strap (WP 0375, Item 35)
Air cleaner barrier curtain removed (WP 0099)
0
0
Locknut (2)
0
Estimated Time to Complete
Lockwasher (4)
0
3.4 hr
0
Personnel Required
Two
0
REMOVAL
0196
1. Remove bolt (Figure 1, Item 1) from right hose cover (Figure 1, Item 2).
2. Remove nut (Figure 1, Item 8), lockwasher (Figure 1, Item 7), bolt (Figure 1, Item 3), washer (Figure 1, Item 4),
spacer (Figure 1, Item 6), clamp (Figure 1, Item 5), and right hose cover (Figure 1, Item 2) from machine.
Discard lockwasher.
Figure 1. Right Hose Cover.
0196