6
TM 5-2420-231-23-2
FIELD MAINTENANCE
-
REAR DRIVE AXLE HOUSING OIL SERVICE
022
0
Check Rear Drive Axle Housing Oil, Drain Rear Drive Axle Housing Oil, Fill Rear Drive Axle Housing Oil
INITIAL SETUP
Tools and Special Tools
Materials/Parts - Continued
Tool Kit, General Mechanic's
Case AKCELA Axle Oil Additive
0
0
(WP 0376, Item 117)
(WP 0375, Item 6)
Gun, Fluid, Direct Delivery (WP 0376, Item 33)
Rag, Wiping (WP 0375, Item 25)
0
0
Handle for D51126 (Bottle Jack)
O-ring (4)
0
0
(WP 0376, Item 36)
Equipment Condition
Jack, Hyd Hand Bottle Type, 20-Ton Capacity
0
Machine parked (TM 5-2420-231-10)
(WP 0376, Item 50)
0
Measure, Liquid, 2 qt (WP 0376, Item 52)
References
0
Pan, Drain, 5 gal. Capacity (WP 0376, Item 54)
WP 0374 (Group Number 0515)
0
0
Trestle, 10-Ton (WP 0376, Item 120) (2)
0
Estimated Time to Complete
Materials/Parts
1.5 hr
0
Case AKCELA MS-1209, Hy-tran Ultra
0
(WP 0375, Item 5)
CHECK REAR DRIVE AXLE HOUSING OIL
0220
NOTE
Machine must be parked on a level surface to perform this check.
1. Remove fill plug (Figure 1, Item 1) and O-ring (Figure 1, Item 2) from rear drive axle (Figure 1, Item 3). Fluid
level should be at the bottom of the fill hole. Add fluid as necessary. Discard O-ring.
2. Install new O-ring (Figure 1, Item 2) and fill plug (Figure 1, Item 1) on rear drive axle (Figure 1, Item 3).
Figure 1. Rear Drive Axle Housing.
0220