8
TM 5-2420-231-23-3
FIELD MAINTENANCE
-
PILOT CONTROL VALVE ASSEMBLY REPAIR
0264
Removal, Disassembly, Cleaning and Inspection, Assembly, Installation
INITIAL SETUP
References - Continued
Tools and Special Tools
Tool Kit, General Mechanic's
0
0
0
Pan, Drain, 5 gal. Capacity (WP 0376, Item 54)
WP 0374 (Group Number 0715 and 0728)
0
0
Materials/Parts
Personnel Required
Cap Set, Protective, Dust and Moisture
Two
0
0
Equipment Conditions
0
0
0
Batteries disconnected (WP 0157)
Locknut (2)
0
0
O-ring (19)
Estimated Time to Complete
0
5.0 hr
References
0
TM 5-2420-231-10
0
WARNING
Allow hydraulic system to cool before performing procedure. Hot metal parts can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Plug and cap all hoses and fittings to prevent contamination. Failure to follow this caution
may result in damage to the machine.
NOTE
Tag and mark lines to aid in installation.
0264-1