TM 5-2420-231-23-3
0275
REMOVAL CONTINUED
4. Disconnect hose (Figure 3, Item 1) from backhoe dipper cylinder (Figure 3, Item 2).
5. Disconnect hose (Figure 3, Item 3) from backhoe dipper cylinder (Figure 3, Item 2).
NOTE
Note position of fitting to aid in installation.
6. Loosen nut (Figure 3, Item 6) and remove fitting (Figure 3, Item 4) and O-ring (Figure 3, Item 5) from backhoe
dipper cylinder (Figure 3, Item 2). Discard O-ring.
Figure 3. Dipper Cylinder Hoses.
0275