TM 5-3805-255-14
0100
INSTALLATION CONTINUED
Figure 14. Lines Attachment.
0100
12. With three bolts loosely installed, remove pivot bracket capscrew (Figure 15, Item 1). Adjust support (Figure
15, Item 4) and bracket (Figure 15, Item 2) so that with these parts tightened, pivot bolt (Figure 15, Item 3) can
be inserted freely through bracket and support. Install pivot bolt. Tighten two bolts (Figure 15, Items 1 and 3)
securely.
Figure 15. Injection Pump Adjustable Support with Bracket.
0100
0100-11