TM 5-3805-262-203-9. STARTING SYSTEM TROUBLESHOOTING (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION1. STARTER DOES NOT CRANK (Cont).Step 8.At relay bracket,o f s t a r t e r r e l a y.T e l l a s s i s t a n t toMultimeter shoulda . I f m u l t i m e t erb . I f m u l t i m e t e rconnect multimeter between small center terminalsplace ignition key switch in start position.i n d i c a t e 2 4 v o l t s.indicates 24 volts, go to step 10 below .indicates zero, go to step 9 below.from starter relay terminal andStep 9.Disconnect multimeter negative leadconnect to chassis frame.T e l l a s s i s t a n t t o p l a c e i g n i t i o n k e y s w i t c h i n s t a r t p o s i t i o n.Multimeter should indicate 24 volts.a .b .If multimeter indicates 24 volts, check ground wire connectionbetween starter relay terminal and mounting lug. Tighten connec-tions or replace wire as necessary.If multimeter indicates zero, check wiring connection betweenn e u t r a l s t a r t s w i t c h a n d s t a r t e r r e l a y t e r m i n a l . R e p a i r o r r e -place wiring as necessary.3-65