TM 5-3805-262-20
INSTALLATION
(1)
(2)
(3)
( 4)
( 5)
(6)
( 7)
(8)
(9)
( l 0 )
(11)
In operator-s compartment, position relay socket assembly (10) with wires
on floor below left-hand instrument panel. Route long white-black wire to
auxiliary steering pump and motor as noted during removal.
At auxiliary steering pump and motor, connect relay socket assembly (10)
white-black wire terminal using lock washer and nut (page 5-88).
At top of relay socket assembly (10), install two relays (9) by alining
tang on relay base with slot in relay socket and pushing firmly.
Install relay socket assembly (10) black wire and wire (8) terminals on
one screw (6) and lock washer (7).
At left side plate, install relay socket assembly (10) using two lock
washers (7), screws (6), lock washers (5), and nuts (4).
At rear of buzzer, connect relay socket assembly (10) white-black wire
and wire (8) terminals as tagged using two screws (3).
Connect two flow switch wiring harness terminals to relay socket assembly
(10) wire terminals by grasping with fingers, alining, and firmly pushing
them together.
Connect two black-white wire terminals to connector (2) by grasping with
fingers, alining, and firmly pushing them together.
Connect wire (1) terminals to front wiring harness terminal and connector
(2) by grasping with fingers, alining, and firmly pushing them together.
Spray terminals at rear of buzzer with electrical cleaner and allow to
a i r d r y . T h e n s p r a y t e r m i n a l s w i t h e l e c t r i c a l s e a l e r.
Connect and tighten battery ground cable (page 5-151).