REMOVAL (SHEET 3 OF 3)(14) Using a hammer and chisel, cuta slot in diaphragm (13). Put apry bar in slot and bend top ofslot out and bottom of slot in.This will distort diaphragm toallow its easy removal.(15) Pull diaphragm (13) with oilseal (12) installed from con-verter ground sleeve and dis-card.NOTEDo not perform followingstep unless inspectionLEGEND1.2*3.4.5.6.7.8.9.10.11.12.13.14015.16.17.18,19.20.21.22.23.plug (14) fromverter housingDiscard plug.Capscrews (6)Retaining plateFlex plate disksFlex plate diskLock nuts (24)Converter coverSealRetaining ringStatorSpacerSealOil sealDiaphragmPlugTurbine pins (6)TurbineTurbine assemblyBearingRetaining ringBearingTurbine housingCapscrews (12)Lock plates (6)TM 5-3805-262-344-97