TM 5-3805-262-344-3. TRANSMISSION MAINTENANCE (CONT)g. OutputShaft(Cont).INSTALLATION ( SHEET 1 OF 3)(1)(2)(3)(4)(5)(6)(7)(8)(9)If plug (13) was removed, apply non-hardening sealant to outside diameterof plug. Install plug in transmission housing bore.Put bearing (7) on output shaft (8) then position output shaft inhydraulic press. Press bearing onto output shaft using 2-1/8 inchesinside diameter sleeve bearing on inner race of bearing.Start output shaft (8) andbearing (7), splined end first,into transmission housing.Install transfer gear (9) intransmission housing. Hold Uptransfer gear and start outputshaft into transfer gear. Alinesplines of output shaft withsplines in transfer gear. Pulloutput shaft until bearing (7)on opposite end of output shaftis in transmission housing. Ifnecessary, use 2-1/8 inchesinside diameter sleeve bearingon inner race of bearing andsoft hammer to push bearinginto position.Install retaining ring (6) tohold bearing (7) and outputshaft (8) in position.Using hammer, start new oilseal (5) into transmissionhousing.Use 3-1/2 inches outside diame-ter sleeve bearing on outerdiameter of oil seal (5) todrive oil seal into transmis-sion housing. Drive oil sealuntil it stops moving.Lubricate lip of oil seal (5)with lubricating oil.Install output flange (4) onoutput shaft (8).Install new O-ring (3) on out-put flange (4).4-192
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business