TM 5-3805-262-343-25. BUCKET HEIGHT CONTROL MAINTENANCE (CONT) CLEANINGa.Clean knob (5) using detergent and water solution. Dry using clean cloth.Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.Wear protective goggles and gloves and use only in a well ventilatedarea. Avoid contact with skin, eyes and clothes and don’t breathevapors. Do not use near open flame or excessive heat and don’t smokewhen using it. Failure to do so could cause serious injury. If you be-come dizzy while using cleaning solvent, get fresh air and medicalattention immediately.If contact with skin or clothes is made, flushwith large amounts of water. If contact with eyes is made, wash eyeswith water and get medical aid immediately.b.Clean remaining parts using cleaning solvent P-D-680. Dry using cleancloths.INSPECTIONa.Inspect spring (11) for cracks, breaks, or permanent set.b.Inspect all other parts for cracks, deformation, distortion, or threaddamage.c.Using micrometer and bore gage, check inside diameter of bushings (13) intwo places 90 degrees apart. Replace bushings if inside diameter is morethan 0.555 inch.3-734