• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Machine Control System - Continued.
Table 2. Machine Control System - Continued.

Manual 1 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  505    506    507    508    509  510  511    512    513    514    515  
img
. .
TM 5-3805-290-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 2. Machine Control System - Continued.
(MID 081)
TEST OR INSPECTION
CORRECTIVE ACTION
CID FMI CODE
2. Check harness.
1. If resistance is greater than 5,000
0096 04 -
(a) Sender remains disconnected from
Ohms, replace machine ECM (WP
Cont.
wiring harness.
0052 00).
(b) Turn battery disconnect switch and
2. If resistance is less than 5,000 Ohms,
engine start switch to OFF position
there is a short between frame ground
(TM 5-3805-290-10).
and signal circuit in wiring harness.
(c) Disconnect J1 and J2 wiring harness
Replace wiring harness in question
connectors from ECM.
(WP 0169 00 thru WP 0175 00).
(d) At sender wiring harness connector,
measure resistance between signal
contact 1 (wire 447 PK) and frame
ground.
0177 03
427-B1850
N OT E
This test procedure may create other diagnostic codes. Ignore these created diag-
nostic codes and clear diagnostic codes when original diagnostic code has been
corrected. Ensure diagnostic code CID 0473 FMI 03 is active before performing
this procedure.
0009 00-13