6
TM 5-3805-290-23-2
ETHER STARTING AID REPLACEMENT
THIS WORK PACKAGE COVERS
Ether Starting Aid Valve and Hardware: Removal, Installation
Ether Starting Aid Line: Removal, Installation
INITIAL SETUP
Equipment Conditions
Maintenance Level
Machine parked on level ground (TM 5-3805-290-
Unit
10)
Tools and Special Tools
Work tool lowered to ground (TM 5-3805-290-10)
Parking brake engaged (TM 5-3805-290-10)
Wheels chocked
Materials/Parts
Battery disconnect switch in OFF position (TM 5-
3805-290-10)
Drawings Required
Lockwasher (2)
TM 5-3805-290-23P, Figures 27 and 28
Personnel Required
Estimated Time to Complete Task
1.0 hr
MOS 62B, Construction Equipment Repairer
WARN I N G
Ether is extremely flammable and toxic. DO NOT smoke, and perform this service in well-ventilated area
away from heat, open flames, or sparks. Wear eye protection. Avoid contact with skin and eyes and avoid
breathing ether fumes. If fluid enters, or fumes irritate eyes, wash immediately with large quantities of
clean water for 15 minutes. Seek medical attention immediately if ether is inhaled or causes eye irritation.
Failure to follow this warning may result in serious injury or death to personnel.