• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 4. Implement Control.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  667    668    669    670    671  672  673    674    675    676    677  
img
. . .
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check supply voltage at implement
0041 04
ECM.
(a) Turn battery disconnect and engine
start switches to ON position (TM
5-3805-291-10).
(b) Check voltage at connector of
1. If voltage is 8.0 0.5 DCV, sensor supply
implement ECM from contact J1-
voltage is correct. If diagnostic code is
44 (sensor supply) to contact J1-45
still present, implement ECM has failed.
(ground). Do not disconnect wiring
It is unlikely that implement ECM has
harness from implement ECM (WP
failed. Repeat this procedure. Also,
0060 00).
recheck if diagnostic code is active. If
cause of diagnostic code is not found,
replace implement ECM (WP 0060 00).
2. If voltage is NOT 8.0 + 0.5 DCV, sensor
supply voltage is not correct. Go to Test
2.
2. Check for a short to ground.
(a) Turn engine start and battery
disconnect switches to OFF
position (TM 5-3805-291-10).
(b) Disconnect wiring harness from
implement ECM (WP 0060 00).
(c) At wiring harness connector for
1. If resistance is greater than 5,000 Ohms,
implement ECM, measure
wiring harness circuit resistance is
resistance between frame ground
correct and implement ECM has failed.
and contact J1-44 of sensor supply
Exit this procedure and repeat this
circuit.
procedure. Also, recheck if diagnostic
code is active. If cause of diagnostic code
is not found, replace implement ECM
(WP 0060 00).
2. If resistance is less than 5,000 Ohms,
wiring harness or a sensor has failed. Go
to Test 3.
3. Disconnect sensors.
(a) Engine start and battery disconnect
switches remain in OFF position
(TM 5-3805-291-10).
(b) One at a time, disconnect any
sensor that uses sensor supply
voltage from wiring harness (WP
0237 00).
0009 00-163


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.