Table 4. Implement Control - Continued.
Table 4. Implement Control - Continued.

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  681    682    683    684    685  686  687    688    689    690    691  
img
. .
TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(e) Check status of CID 0350 FMI 03. 1. If CID 0350 FMI 03 is not active, initial
0350 03 - Continued.
diagnostic code was probably caused by
poor electrical connection or short at
wiring harness connectors that was
disconnected and reconnected. Resume
normal machine operation.
2. If CID 0350 FMI 03 is active, exit this
procedure and repeat this procedure. If
cause of this diagnostic code is not found,
replace implement ECM (WP 0060 00).
427-C1652
N OT E
0350 04
Ensure diagnostic code is active and diagnostic code indicator is active.
The following procedure can create num rous related diagnostic codes. Recon-
e
nect all harnesses. Then, related diagnostic codes will be shown as being NOT
active. Complete following procedure. Then, clear all of related diagnostic codes.
1. Connect MSD (WP 0005 00) and check
1. If diagnostic code remains active, go to
for diagnostic codes.
Test 2.
2. If diagnostic code is not active, wiring
harness is correct and implement ECM is
operating properly, sensor has failed.
Replace sensor (WP 0085 00).
0009 00-177