TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Check wiring harness.
0350 08 - Continued.
(a) Sensor remains disconnected from
wiring harness.
(b) Battery disconnect switch remains
in OFF position (TM 5-3805-291-
10).
(c) Disconnect wiring harness from
implement ECM (WP 0060 00).
1. If resistance is greater than 5,000 Ohms,
(d) At wiring harness connector for
exit this procedure and repeat this test. If
implement ECM, measure
diagnostic code is not found, replace
resistance between signal contact C
implement ECM (WP 0060 00).
(wire C530-BU) and frame ground.
2. If resistance is less than 5,000 Ohms,
short is between frame ground and signal
circuit in wiring harness. Replace wiring
harness in question (WP 0195 00 thru
WP 0201 00).
Connect MSD (WP 0005 00) and check
0350 13
calibration.
(a) Calibrate lift linkage position
sensor (WP 0017 00).
(b) Ensure diagnostic code is active.
(c) Observe ON/OFF status of
1. If diagnostic code indicator is inactive,
diagnostic code indicator as lift arm
calibration corrected diagnostic code.
is fully raised and fully lowered.
Clear diagnostic code.
2. If diagnostic code indicator is active,
perform calibration for rotary position
sensor again. Also, ensure diagnostic
code indicator is active for this diagnostic
code. If cause is not found, replace sensor
(WP 0085 00) and repeat calibration. If
this does not eliminate diagnostic code,
replace implement ECM (WP 0060 00).
If fault becomes active, it is possible that
mounting for sensor may be loose.
Mounting should be checked.
0009 00-180