TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Reconnect implement lockout
0490 04 - Continued.
switch.
(d) Disconnect wiring harness from
implement ECM (WP 0060 00).
1. If continuity agrees with values in Switch
(e) Activate switch. At wiring harness
connector implement ECM, check
package, wiring harness circuit is
continuity to ground of normally
correct. Exit this procedure and repeat
closed contact and normally open
this troubleshooting procedure. If cause
contact.
of diagnostic code is not found, replace
implement ECM (WP 0060 00).
2. If continuity check does not agree with
end of this work package, replace wiring
harness in question (WP 0195 00 thru
WP 0201 00).
427-C1666
N OT E
0491 03
All solenoid return lines connect to contact J1-60 (wire J813-BK) of implement
ECM.
The following test procedure may create other diagnostic codes. Ignore these
created diagnostic codes and clear diagnostic codes when original diagnostic
code has been corrected.
Ensure diagnostic code is active and diagnostic code indicator is active.
This test causes implement ECM to logan open circuit diagnostic code for this
solenoid. Clear this code from implement ECM after troubleshooting.
1. Check solenoid.
(a) Turn engine start switch to OFF
position (TM 5-3805-291-10).