TM 5-3805-291-23-1
TROUBLESHOOTING WITH A DIAGNOSTIC CODE - CONTINUED
0009 00
Table 4. Implement Control - Continued.
(MID 082)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
(c) Disconnect wiring harness from
0491 06 - Continued.
implement ECM (WP 0060 00).
(d) At wiring harness connector for
implement ECM, measure
(continuity), harness has failed. Replace
resistance between contact for
wiring harness in question (WP 0195 00
thru WP 0201 00).
E920-BR) and contact J1-60
(ground) (wire J813-BK).
is correct. Exit this procedure and repeat
this troubleshooting procedure. Also,
recheck if diagnostic code indicator is
active for this diagnostic code. If cause is
not found, replace implement ECM (WP
0060 00).
N OT E
0491 13
Ensure diagnostic code is active.
(a) Calibrate main control valve (WP
(b) Recheck diagnostic code.
(c) Ensure diagnostic code is active.
(d) Observe ON/OFF status of
1. If diagnostic code indicator is inactive,
diagnostic code indicator as
calibration corrected diagnostic code.
auxiliary function is fully actuated.
Clear diagnostic code.
2. If diagnostic code indicator is active,
Also, ensure diagnostic code indicator is
active for this diagnostic code. If cause is
calibration again. If this does not
eliminate diagnostic code, replace
implement ECM (WP 0060 00).