MAIN HYDRAULIC CONTROL VALVE INSTALLATION
MAIN HYDRAULIC CONTROL VALVE INSTALLATION - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1145    1146    1147    1148    1149  1150  1151    1152    1153    1154    1155  
img
TM 5-3805-291-23-2
MAIN HYDRAULIC CONTROL VALVE REPLACEMENT - CONTINUED
0218 00
MAIN HYDRAULIC CONTROL VALVE INSTALLATION - CONTINUED
3.
With assistance, attach shackle assembly to front
frame of machine. Attach lever puller hoist and link
bracket to shackle assembly and position main
hydraulic control valve (20) on machine.
427-C1113
4.
Install five washers (37) and bolts (36) on front and
rear of main hydraulic control valve (20).
427-C1109