TM 5-3805-292-23
0078
C AU T I O N
Cap all hydraulic hose and line ends along with component connections during removal to
protect against contamination. Failure to follow this caution may result in damage to
equipment.
N OT E
Tag all hoses and linesto aid in installation.
Use a container to catch any fluid that maydrain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.
REMOVAL
00078
1. Disconnect line (Figure 1, Item 1) from tandem pump (Figure 1, Item 6).
N OT E
One line is disconnected on bottom of tandem pump.
2. Disconnect four lines (Figure 1, Item 2) from tandem pump (Figure 1, Item 6).
3. Disconnect four lines (Figure 1, Item 5) from tandem pump (Figure 1, Item 6).
4. Loosen clamps (Figure 1, Items 3 and 7) and disconnect lines (Figure 1, Items 4 and 8) from tandem pump
(Figure 1, Item 6).
Figure 1. Tandem Pump.
0078