• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Control Handle.
Figure 3. Joystick Valve.

Field Maintenance Manual For M400T And M400W
Page Navigation
  578    579    580    581    582  583  584    585    586    587    588  
img
.
TM 5-3805-292-23
0084
REMOVAL CONTINUED
7. Disconnect six hydraulic hoses (Figure 2, Item 2) from joystick valve (Figure 2, Item 1).
8. Remove joystick valve (Figure 2, Item 1) from machine.
Figure 2. Joystick Valve.
0084
END OF TASK
CLEANING AND INSPECTION
00084
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
1. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.
0084-3