Figure 2. Joystick Valve.
Figure 4. Control Handle.

Field Maintenance Manual For M400T And M400W
Page Navigation
  579    580    581    582    583  584  585    586    587    588    589  
img
.
TM 5-3805-292-23
0084
CLEANING AND INSPECTION CONTINUED
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
2. Dry parts with compressed air.
3. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
INSTALLATION
00084
1. Connect six hydraulic hoses (Figure 3, Item 2) to joystick valve (Figure 3, Item 1).
2. Install joystick valve (Figure 3, Item 1) on machine.