0087
FIELD MAINTENANCE
-
TILT CYLINDER MAINTENANCE
0087
REMOVAL, DISASSEMBLY, CLEANING AND INSPECTION, ASSEMBLY, INSTALLATION
INITIAL SETUP
Tools and Special Tools
Materials/Parts - Continued
0
0
Tool Kit, General Mechanic's (WP 0178, Item
O-ring (3)
0
33)
0
Personnel Required
0
SATS (WP 0178, Item 30)
0
2
Wrench, Torque, Click, Ratcheting, 3/4 in.
0
Drive, 600 lb-ft (contained in SATS) (WP
References
0
0178, Item 41)
0
TM 5-3805-292-23P, Figure 54, 56
0
Materials/Parts
0
Equipment Conditions
0
Cap Set, Protective (WP 0179, Item 2)
0
Loader arms lowered (TM 5-3805-292-10)
0
Cleaning Compound, Solvent, Type III (WP
Machine parked on level ground (TM 5-3805-
0179, Item 3)
0
292-10)
0
Oil, Lubricating, OE/HDO-10 (WP 0179, Item
Parking brake engaged (TM 5-3805-292-10)
16)
0
0
Hydraulic pressure relieved (WP 0172)
Rag, Wiping (WP 0179, Item 19)
0
0
Sealing Compound (Loctite 243) (WP 0179,
Estimated Time to Complete
0
Item 22)
0
2.0 Hr
0
Tag, Marker (WP 0179, Item 30)
0
Kit, Seal
0
WARN I N G
When servicing this machne, performing maintenance, or disposing of hazardous
i
materials, consult your unit/local hazardous waste disposal center or safety office for local
regulatory guidance. If further information is needed, please contact The Army
Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system lines or fitting unless engine is shut
down and hydraulic system pressure has been relieved. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin.
At operating temperature, hydraulic oil is hot.Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
N OT E
Use a container to catch any fluid that may drain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.
0087-1