Figure 12. Main Hydraulic Valve.
Figure 14. Main Hydraulic Valve.

Field Maintenance Manual For M400T And M400W
Page Navigation
  627    628    629    630    631  632  633    634    635    636    637  
img
.
TM 5-3805-292-23
0089
INSTALLATION
00089
N OT E
Main hydraulic valve weighs 40 lb (18 kg).
Install all hoses, lines, fittings, and wiring harnesses as tagged during removal.
1. Install main hydraulic valve (Figure 13, Item 15), four washers (Figure 13, Item 17), and two bolts (Figure 13,
Item 16) on machine.
2. Install three fittings (Figure 13, Item 14) and hoses (Figure 13, Item 13) on main hydraulic valve (Figure 13,
Item 15).
3. Install nine fittings (Figure 13, Item 2) and lines (Figure 13, Item 1) on main hydraulic valve (Figure 13,
Item 15).
4. Install bracket (Figure 13, Item 5), bolt (Figure 13, Item 6), washer (Figure 13, Item 4), and new locknut (Figure
13, Item 3) on main hydraulic valve (Figure 13, Item 15).
5. Install plate (Figure 13, Item 12), bracket (Figure 13, Item 11), two bolts (Figure 13, Item 8), pin (Figure 13, Item
10), and clip (Figure 13, Item 9) on main hydraulic valve (Figure 13, Item 15).
6. Connect electrical connector (Figure 13, Item 7).